| 01Model | PPIT-T1-01 |
|---|
| 02Projection dimensions, positive-pressure room | 7.15 m × 5.0 m × 3.0 m (±50 mm); shoulder height 2.10 m (±30 mm); projected area 35.7 m² |
|---|
| 03Projection dimensions, buffer room | 1.50 m × 1.78 m × 2.49 m (±50 mm); shoulder height 2.16 m (±30 mm); projected area 2.67 m² |
|---|
| 04Internal dimensions, positive-pressure room | 6.67 m × 4.52 m × 2.76 m (±50 mm); shoulder height 1.93 m (±30 mm); internal area 30.1 m² |
|---|
| 05Internal dimensions, buffer room | 1.26 m × 1.30 m × 2.25 m (±50 mm); shoulder height 2.00 m (±30 mm); internal area 1.63 m² |
|---|
| 06Outer cover | 750 g/m² white PVC, with a 300 mm (±50 mm) soil-burial / anchoring skirt along the bottom edge |
|---|
| 07Air column | 0.7 mm gray PVC; main air-column structure made with high-frequency heat-welding / heat-sealing |
|---|
| 08Inner lining | Buffer room: white Shumei silk fabric. Positive-pressure room: transparent TPU liner |
|---|
| 09Floor covering | 420 g/m² gray PVC groundsheet |
|---|
| 10Doors | Buffer-room outer door 1000 × 1700 mm (±50 mm), U-shaped airtight zipper, 200 mm (±50 mm) above ground, qty 1. Buffer-room inner-lining door 1000 × 1900 mm (±50 mm), roll-up with two zippers, qty 1. Door between rooms 1000 × 1700 mm (±50 mm), U-shaped airtight zipper, 200 mm (±50 mm) above ground, qty 1. Rear door of positive-pressure room 1000 × 1700 mm (±50 mm), U-shaped airtight zipper, 200 mm (±50 mm) above ground |
|---|
| 11Windows | 695 × 615 mm (±50 mm), 8 in total (2 in buffer room, 6 in positive-pressure room), each with a window cover and heat-sealed transparent film |
|---|
| 12Working pressure | 18 to 22 kPa (2.5 to 3.5 psi) |
|---|
| 13Operating temperature | −30°C to 70°C |
|---|
| 14Wind resistance | Grade 8 or higher |
|---|
| 15Inflation time | 6 to 9 minutes |
|---|
| 16Estimated weight | 260 kg |
|---|
| 17Estimated packed size | 1.3 m × 1.2 m × 1.2 m (L × W × H) |
|---|
| 18Packaging | Fabric wrapping / bag with large carrying handles |
|---|
| 19Inflation / deflation system | Two valve sets on the air columns (one set with 2 inflation/deflation valves and 1 safety valve; one set with 2 inflation/deflation valves). Two electric inflation/deflation pumps, 220 to 240 V, 50 Hz, 2000 W, 3.45 kg each |
|---|
| 20Anchoring | 300 mm (±50 mm) soil-burial / anchoring skirt; can be combined with sandbags in severe environments |
|---|
| 21Ventilation ports | Ø400 mm, with covers and sleeves, qty 2, at the rear-door area of the positive-pressure room |
|---|
| 22Functional ports | With covers and sleeves, qty 3 (2 at the rear-door area of the positive-pressure room, 1 in the buffer room) |
|---|
| 23Air-conditioning port | One transparent TPU ventilation duct; external connection Ø400 mm (±20 mm), reducing to Ø250 mm (±20 mm) inside; air-distribution holes along the duct; can be adjusted to actual equipment |
|---|
| 24Positive-pressure control | Pressure inside the tent can be automatically adjusted / set through the equipment |
|---|
| 25Lamp-hanging points | 9 (1 in buffer room, 8 in positive-pressure room) on the sloped roof air columns |
|---|
| 26Cable management | Hook-and-loop cable fixing points from the valve position along the air column to the top lamp-hanging points |
|---|